Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
26405 | MARATHON SPECIAL PRODUCTS CORPORATIO |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.438 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.438 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1100.0 |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.500 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.422 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
ABGN | BOARD OVERALL LENGTH | 7.750 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.156 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
ABGS | BASE THICKNESS | 0.312 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.422 INCHES |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 16 SINGLE |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 SINGLE |
AMPS | CURRENT RATING IN AMPS | 20.0 |
CSCR | TERMINAL CONNECTING LINK TYPE | 2 SINGLE |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
AAMA | MOUNTING HOLE DIAMETER | 0.175 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.351 INCHES |
ABGP | BOARD OVERALL WIDTH | 1.128 INCHES |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 16 SINGLE |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
ABGQ | BOARD OVERALL HEIGHT | 0.500 INCHES |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.438 INCHES |
AAQL | BODY STYLE | BARRIER TYPE |